CR vs DR for veterinary practices

Both replace film. They differ in what happens between the exposure and the image on screen, and that difference repeats on every study you take.

How each one works

Computed radiography (CR) keeps the familiar cassette. Inside is a reusable phosphor imaging plate instead of film. After the exposure, a technician carries the cassette to a reader that scans the plate and produces a digital image. The plate is erased and used again.

Digital radiography (DR) replaces the cassette with a flat panel detector connected to the computer. The image appears on screen moments after the exposure, with nothing to carry or scan.

Side by side

FeatureCRDR
Image on screenAbout 30 seconds with the IWV CR eco, after carrying the cassette to the reader2 to 5 seconds with System X; image capture in 3 to 5 seconds with the IWV FP
RetakesRepeat the cassette, carry and scanRetake while the patient is still in position
Existing tableWorks with your current tableIWV FP fits most tables; System X includes a new one
What you addA reader, cassettes and a workstationA detector, or a complete room
Daily handlingCassettes and plates to manageNo cassettes
File formatsDICOM 3.0, TIFF, BMP, JPEG (IWV CR eco)DICOM 3.0 (System X)

When CR is the right call

CR gets a practice with a sound table off film without replacing the table. The IWV CR eco is compact (6 x 18 x 32 inches), produces 16-bit images with 65,536 levels of grey, and reads plates flat so they are never bent.

When DR pays for itself

The time difference repeats on every study. In a busy practice, seconds instead of a walk to the reader add up to less time under anesthesia, faster answers for clients and more studies in a day. If your table is sound, the IWV FP upgrades the image without a new room. If you are replacing the room, System X installs a complete DR system on a 110 V circuit.

Moving from CR to DR

IWV offers trade-in and trade-up incentives for practices moving off CR, and System X and the IWV CR eco are DICOM 3.0 compatible so your images keep moving to specialists and your practice software.

Frequently asked questions

What is the difference between computed radiography and digital radiography?

Computed radiography (CR) captures the image on a reusable phosphor plate inside a cassette, which a reader then scans into a digital image. Digital radiography (DR) captures the image on a flat panel detector that sends it straight to the computer, with no cassette to handle.

Is DR faster than CR?

Yes. With IWV systems a CR plate is processed in about 30 seconds after you carry it to the reader, and a DR image is on screen in 2 to 5 seconds with System X, or captured in 3 to 5 seconds with the IWV FP.

Can I keep my x-ray table with CR or DR?

Yes for both. The IWV CR eco works with your current table, and the IWV FP flat panel fits most existing tables. A complete DR room like System X replaces the table as well.

Talk it through with an imaging consultant

Tell us how your practice works. A consultant will match you with the right system, explain trade-in options and send a quote.

(303) 996-8489
  • One company sells, installs, trains and supports it
  • Trade-in and trade-up incentives on film, CR and older sensors
  • Headquartered in Englewood, Colorado
What do you need?

Up to 1,500 characters.

or call (303) 996-8489

Fields marked with an asterisk are required. We use your details only to answer this request. Privacy policy.